EasyManuals Logo

Symmetricom XLi User Manual

Symmetricom XLi
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #128 background imageLoading...
Page #128 background image
XLi Time & Frequency System 117
XLi-man, Issue 8, 6/17/2008, Rev. H
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
To change the Code Output selection enter:
F90 IRIG-B DC<CR>
XLi responds:
OK<CR><LF>
Sample request for Time Code Out with IEEE 1344 extensions: F90<CR>
Response: F90 IRIG-120 1344
To enter the Code Output selection, send the following character string to the Serial/
Network port:
Sample entry: F90<SP>IRIG-B DC<CR>
Response: OK<CR><LF>
To enter the Code Output selection for Time Code with IEEE 1344 extensions, send the
following character string to the Serial/Network port:
F90<SP><CODE OUTPUT><CR>
where:
F = ASCII character F.
90 = function number.
<SP> = space
<CODE OUTPUT> = IRIG-B120 1344 or IRIG-B000 1344
<CR> = carriage return character.
<LF> = line feed character.
Sample entry: F90<SP>IRIG-B120 1344<CR>
Response: OK<CR><LF>
The Serial/Network port will respond with the message “ERROR 01 VALUE OUT OF RANGE” if
the input string was in the correct format but contained a value, probably numeric,
that was out of the range of acceptable values.
The Serial/Network port will respond with the message “ERROR 02 SYNTAX” if it receives
a string in an incorrect format.
The Serial/Network port will respond with the message “ERROR 03 BAD/MISSING FIELD” if
the input string lacks a required field.
IRIG-B120 1344
F100 – Network Port Configuration & XLi Firmware
F100 provides two groups of commands:
Group 1, available through the keypad/display and the command line, provides access to
network port settings and hardware/Firmware status information.
Group 2, available through the command line only, provides commands for changing system
firmware, changing NTP & SNMP parameters, changing the user name/password, resetting the
unit, and pinging other network devices.
Warning: The F100 commands have the capacity to remove the XLi from the network and disable the
XLi’s system firmware. Use judiciously.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi and is the answer not in the manual?

Symmetricom XLi Specifications

General IconGeneral
BrandSymmetricom
ModelXLi
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals