226 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
24 VDC Power Input Option (87-8012-24)
48 VDC Power Input Option (87-8012-48)
Input connector: Removable three-position screw terminal block
Input voltage range: 18-36 VDC, 105 watts, 8 amps
Isolation, ground: Input is fully floating. Either input polarity may be strapped to
chassis ground at the input terminal block.
Isolation: Input to output: 500 VAC minimum
Fan: Exhaust 3-6CFM
Input connector: Removable three-position screw terminal block
Input voltage range: 36-60 VDC, 105 watts, 4 amps
Isolation, ground: Input is fully floating. Either input polarity may be strapped to
chassis ground at the input terminal block.
Isolation: Input to output: 500 VAC minimum
Fan: Exhaust 3-6CFM