208 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
5------GND
6------TX- (Code out Minus)
7------PPX Out (PPS/PPM out - for test purposes only)
8------PPX In (PPS/PPM in - for test purpose only)
9------N/C
DIFFERENTIAL OUTPUT LEVELS:
Specified by ICD-GPS-060 Rev B 3.3.2.3
Load: 500
Ω to >=5kΩ
Logic 1: 0.10 to 6.0 Vdc
Logic 0: -0.10 to -6.0 Vdc
Physical: Double high option bay.
CPU-Aware: Yes
Table 10:
Bit # mSec Description
0 0 80’s of hours
1 20 40’s of hours
2 40 20’s of hours
3 60 10’s of hours
4 80 8’s of hours
5 100 4’s of hours
6 120 2’s of hours
7 140 1’s of hours
8 160 80’s of min
9 180 40’s of min
10 200 20’s of min