254 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
other ACTS failure types."
::= { acts 8 }
actsFailedInit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Time server's internal modem failed to initialize. If this is
excessive, it may indicate a time server hardware failure. "
::= { acts 9 }
actsNoDialTone OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Time server's internal modem found no dial tone. This may be
caused by a broken phone line to the time server. "
::= { acts 10 }
actsNoCarrier OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Time server's internal modem found no carrier. No modem was
found at the other end and maybe the phone number for ACTS is wrong."
::= { acts 11 }
actsBusyLine OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Time server's internal modem found ACTS line busy."
::= { acts 12 }
actsNoAnswer OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The remote ACTS mode did not answer the call."
::= { acts 13 }
actsBadReply OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The syntax of the reply from remote modem was incorrect, possibly
due to line noise."
::= { acts 14 }