SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
alarmDataCodeOBJECT-TYPE
SYNTAX SystemAlarmType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The code of the event that generated the alarm."
::= { systemAlarmData 3 }
alarmDataStatusDescriptorOBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A description of the the XLi system at the time the alarm was
triggered. The format matches the output of the F73 command."
::= { systemAlarmData 4 }
alarmSystemNotification NOTIFICATION-TYPE
OBJECTS
{
alarmDataIpAddr,
alarmDataTimeStamp,
alarmDataCode,
alarmDataStatusDescriptor
}
STATUS current
DESCRIPTION
"A trap that indicates a change in system status. Refer to the list of
OBJECTS, above."
::= { xliTrap 1 }
configDataLatchClear OBJECT-TYPE
SYNTAX INTEGER {
latchClear (1)
}
MAX-ACCESS write-only
STATUS current
DESCRIPTION
"Setting to <latchClear> clears the latched fault indicators."
::= { systemFaultConfigData 1 }
configDataThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..99999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time error threshold, in nanoseconds, at which the time error
fault is activated."
::= { systemFaultConfigData 2 }
configDataTimeout OBJECT-TYPE
SYNTAX Unsigned32 (0..86400)
MAX-ACCESS read-write
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com