XLi Time & Frequency System 269
XLi-man, Issue 8, 6/17/2008, Rev. H
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
statusSecondaryPower OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the secondary power."
::= { systemStatusDetail 8 }
statusRbOsc OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the rubidium oscillator."
::= { systemStatusDetail 9 }
statusDac OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the digital to analog convertor."
::= { systemStatusDetail 10 }
statusFirstTimeLock OBJECT-TYPE
SYNTAX INTEGER {
firstTimeLockedOnce (1),
firstTimeLockedOnceWithinTimeout (2),
firstTimeNotLocked (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of clock since power on.
(1)- indicates the clock has locked at least once since power on.
(2)- indicates the clock has locked since power on but is still within
the power on suppress timeout.
(3)- indicates the clock has not locked since power on."
::= { systemStatusDetail 11 }
statusTimeError OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com