60 XLi Time & Frequency System
XLi-man, Issue 8, 6/17/2008, Rev. H
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
F11 responds:
F11 DDD:HH:MM:SS.mmmQ
where:
The time quality character, "Q", is one of the following characters:
Note: F8 does not display milliseconds, regardless of the format defined in F11.
Suppress the “DDD”, “HH”, “MM”, “SS”, “mmm”, and “Q” segments of F11 by placing an “X” (Shift-X) in
the leading position of any segment, followed by any placeholder characters, and the following
separator. For example, to suppress “DDD”, enter:
F11 X--:
To see the resulting change to F11, enter:
F11
F11, with “DDD” suppressed, responds:
F11 XDD:HH:MM:SS.mmmQ
With “DDD” suppressed, the output of F8 would look like this example:
:16:23:32*
<SOH> = ASCII Start-of-Heading character
<CR> = ASCII Carriage Return character
<LF> = ASCII Line Feed character
DDD = day-of-year.
HH = hours.
MM = minutes.
SS = seconds.
mmm = milliseconds.
: = colon separator.
Q = time quality character (see the following table)
SPACE = Time error is less than time quality flag 1's threshold
. = Time error has exceeded time quality flag 1's threshold
* = Time error has exceeded time quality flag 2's threshold
# = Time error has exceeded time quality flag 3's threshold
? = Time error has exceeded time quality flag 4's threshold, or a reference source is unavailable