4. Settings
4-3-3. TEDS calibration
A TEDS sensor has calibration information, including rated out-
put and rated capacity, stored in its memory.
TEDS calibration reads this calibration information to automati-
cally record calibration values.
TEDS loading (TEDS calibration)
c
Zero balancing
c
Unit shown
4-3-3-1. TEDS
By connecting a sensor that supports IEEE1451.4 Transducer
Electronic Data Sheets (TEDS) to the unit, the rated output
stored in the sensor can be loaded and this can be applied to
calibration of the indicator with this function.
In addition, the value calibrated by the unit itself can be loaded
to the TEDS sensor and its original value can be restored. These
functions are supported by TEDS sensors that comply with the
standard shown in the table below.
Note, however that equipment with TEDS memory includes
both 1kbit and 4kbit devices, but the unit only supports 4kbit.
TEDS standard
IEEE
1451.4
(V0.9)
IEEE1451.4 (V1.0)
Template ID
Bridge
Sensors
(33)
Strain Gauge
(35)
Other
-

-
 TEDS calibration, TEDS data writing and TEDS data resto-
ration supported
TEDS calibration supported
- Not supported