6. TERMINAL FILE PROGRAMMING
EO3-11106
6.36 Key Status Programming
6-155
Key Status Table (Key Code 1 to 20)
Bit No. Function SET RESET
1 TOTAL-only TOTAL-only key
2 TENDER-only TENDER-only key
If both SET or RESET:
TOTAL and TENDER
3
-- vacant bit --
4 SHORT TENDERING Prohibited Allowed
5 OVER TENDERING Prohibited Allowed
6
-- vacant bit --
7 NO-PURCHASE CASHING Allowed Prohibited
8 FINALIZING R/A ITEMS Prohibited Allowed
1 CONSIGNMENT Compulsory Free
2
-- vacant bit --
3
DRAWER OPEN AFTER THE KEY
OPERATION (see NOTE below)
Not Open Open
Key Name
Key
Code
1 2 3 4 5 6 7 8 1 2 3
1 R R R
[AT/TL]
2 R
3 R S R R S R
[CHK TEND]
4 R R R
5 S R R R R S
[CRT]
6 R R R
7 R S R R R R
[MISK TEND]
8 R R R
9 R S R S R R
[CPN]
10 R R R
11 S R R R R S
[CREDIT 1]
12 R R R
13 S R R R R S
[CREDIT 2]
14 R R R
15 S R R R R S
[CREDIT 3]
16 R R R
17 S R R R R S
[CREDIT 4]
18 R R R
19 S R R R R S
[CREDIT 5]
20 R R R
NOTE: Regardless of this bit status selection, the drawer opens on over-tendering operation, but does not open
on short-tendering operation.
Description of symbol in the above table:
R = RESET Status
S = SET Status
Those bits marked with either “R” or “S” may be RESET or SET according to your requirements.
= Bit not applicable to the key (Those bits can be SET or RESET.)
Standard Bit status selection auto-preset after a RAM Clear.