EasyManua.ls Logo

TECALEMIT HDA eco - RS422-Connection; LAN Connection

TECALEMIT HDA eco
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44 1670 001-GB-I
HDA eco
25
3.1.5.3 RS422-Connection
In this case data transmission is possible up to a cable length of approx. 1100 yards.
An RS232-to-RS422 converter is required at the PC end and the ‘RS422 socket mo-
dem’ must be plugged in on the HDA eco. The PC must have a free COM port or a USB-
to-RS232 adaptor.
Connection diagram
3.1.5.4 LAN Connection
The link via a cable-connected LAN interface to an existing local network enables
communication to a PC. The PC must be in the same network. For details concerning
the connection and the necessary settings, see chapter 5.3.4.3.10.
Connection diagram
6 5 4 3 2 1
X2
PCB HDA eco
PC
HD
Manager
Converter IC-485SI
1
4
2
3
DCE
DTE
Tx On
Rx On
Plug-in power
supply
IC-485 SI
T+
T
-
R
-
R+
PE
HDA eco
HDA eco
PC
HD
Manager
PCB HDA eco
Local area network

Table of Contents