44 1670 001-GB-I
HDA eco
39
5.3.1.5 USB Report – Refuellings
A report for the dispensing data not marked as already transmitted is saved as a text
file (‘DSPDATA.TXT’) on a USB flash drive. The file can for example be opened with a
text editor on a PC and printed out. The prerequisite for this is that a recordable USB
flash drive is inserted in the USB port provided for it on the automatic dispenser.
Display (e.g.):
File (e.g.):
The dispensing data are not marked as transmitted after the creation of the report.
They will be saved again with a later report. If necessary, it is advisable to manually
‘delete’ the dispensing data (see section 5.3.1.3).
Saving report
1 / 122
HDM eco 1820025
USB Report - Refuelling data
............................
....
Date 24.03.12 Time 12:42
Dispensing data: 1
............................
....
Date 04-19-11 Time 09:24
Driver: 12
Vehicle: 15
Order: 17635
Mileage: 115050 mls
Dispensing: 32.49 L
Dispensing data: 2
............................
....
Date 04
-
20
-
11
Time 02:38

Table of Contents