48 44 1670 001-GB-I
HDA eco
5.3.4.1.4 Order y/n
Display (e.g.):
The entry of an order no. before each refuelling is optional. You can choose between
‘inquire and ‘do not inquire’.
5.3.4.1.5 Nozzle switch y/n
Display (e.g.):
In order to keep the runtime for the pump working against a closed nozzle as short as
possible it is useful to install a nozzle switch. You can choose between ‘yes’ and ‘no’.
The default setting is ‘no’.
5.3.4.1.6 Refuelling limit
Display (e.g.):
The maximum possible dispensing quantity per refuelling operation can be specified
here (absolute limit). A quantity between 5 and 9999 litres can be entered. In case the
vehicle specific limit is lower than it applies.
5.3.4.1.7 Max. Refuelling time
Display (e.g.):
The maximum possible refuelling time per refuelling operation can be specified here.
A value between 1 and 99 minutes can be entered. In case the vehicle specific limit is
lower than it applies.
5.3.4.1.8 Time Out Refuelling
Display (e.g.):
Before configuring the time-out time, it may be necessary to set the unit of the time
interval. Users may choose between minutes and seconds. Minutes are the default. Af-
ter confirming with the <ENTER> key, configuration of the time takes place.
Display (e.g.):
a. Unit set to "Minutes":
The maximum elapsing time during a dispensing event without any medium being dis-
pensed can be specified here. (Example: The nozzle wasn’t replaced after refuelling
Time-out units
Minutes
◄►
OrderNo
◄►query
Refuell. limit
9999 L
Max.refuel.time:
30 min
Time out refuel
2 min
Nozzle switch
◄►no