44 1670 001-GB-I
HDA eco
71
5.3.5.2.3 Height / Maximum Filling Height
Display (e.g.):
The maximum filling height of the tank in mm is entered as value between 0 and
9999.
5.3.5.2.4 Density Medium
Display (e.g.):
In order for the hydrostatic tank probe to work precisely, the density of the tank me-
dium [g/l] must be entered. A value of between 0 and 9.999 can be entered.
5.3.5.2.5 Sensor Type
Display (e.g.):
Input of the sensor type (sensor range). There is a choice of the types 200, 300, 500
and 1000 mbar. The selection of the type of sensor is made according to the height of
the tank. Hence, 200 mbar correspond to 200 cm water gauge or 230 cm diesel
gauge, 300 mbar to 300 cm water gauge or 340 cm diesel gauge and so on.
5.3.5.2.6 Offset Sensor
Display (e.g.):
Offset entry [mm] (corresponds to the effective installation height of the sensor rela-
tive to the floor of the tank). Using the ‘’ button at the first position, with ‘-‘ it is pos-
sible to enter a negative offset (e.g. when the sensor is installed below the tank floor
or inclined tank). A value of -999 to 9999 mm can be entered.
5.3.5.2.7 Min. Volume / Cut Off Volume
A limit value can be entered here, below further refuelling with the HDA eco will be
disabled.
The value is checked before and during each refueling. The active refueling will be
stopped to prevent dry running of the pump. The disablement is automatically can-
celled after refilling the tank or switching the tank monitoring off.
Display (e.g.):
A value of 0 to MaxVol (see 5.3.5.2.2) can be entered.
Tank parameters
◄►Height 1600 mm
Tank parameters
◄►Dens. 860 g/L
Tank parameters
◄►Sensor 200 mbar
Tank parameters
◄►Offset 11 mm
Tank parameters
◄►MinVol 5000 L