ER-
ROR
CODE
ERROR DESCRIPTION SOLUTION
15 LOSS OF IMPULSE [*] - Perform a factory reset (802 =1, then 800
=1) + standard settings; For details, see:
$6.5 PROCEDURE FOR RESTORING
THE LOW KIT FACTORY SETTINGS.
- Check the motor side encoder connec-
tor contacts. They must be “regular” and
not enlarged or stretched out [1].
- Check that a secondary ferrite is present
for the motor encoder harness, inside the
machine. Check that the two ferrites are
properly closed.
- Open the switch box and check the
presence of light-blu ferrite.
- If the error persists over time: replace
the motor-encoder group.
16 MOVEMENT OF THE RUNNING SUR-
FACE DURING THE HOLD PHASE[*].
Hold phase: block of the running surface:
the slats are blocked, providing the user
with a stable surface while climbing onto
the treadmill.
- Check the motor side encoder connec-
tor contacts. They must be “regular” and
not enlarged or stretched out [1].
- Check that a secondary ferrite is present
for the motor encoder harness, inside the
machine. Check that the two ferrites are
properly closed.
- Check that two ferrites are present in-
side the power supply box. Also check
that these ferrites are properly closed.
- If the error persists over time: replace
the motor-encoder group.
17 ACCELERATION OF THE RUNNING
SURFACE DURING THE HOLD PHA-
SE[*]
Hold phase: block of the running surface:
the slats are blocked, providing the user
with a stable surface while climbing onto
the treadmill.
.
- Check the motor side encoder connec-
tor contacts. They must be “regular” and
not enlarged or stretched out [1].
- Check that a secondary ferrite is present
for the motor encoder harness, inside the
machine. Check that the two ferrites are
properly closed.
- Check that two ferrites are present in-
side the power supply box. Also check
that these ferrites are properly closed.
TECHNOGYM RUN Technical Service Guide
Rev. 1.0
- 73 -TSG-00284-EN- Uncontrolled copy if printed