SYNCHRO EXCITE Class & Trend: Service & maintenance manual - rev. 2.0
Page 9.23
9.4.1.3. Default Setting
To load the default parameter values, scroll using the +/- effort level keys until the display shows:
DEFAULT SETTING ?
press ENTER to write the default values to the low kit, and return to the upper menu level by
pressing CLEAR for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.
9.4.1.4. Table of configuration parameters
Parameter Description Defaultvalues
Par 01 Transmission ratio 141
Par 02 Speed ratio (integer part) 1
Par 03 Minimum braking current (standby pos.) [mA] 0
Par 04 Maximum continuous power [W] 200
Par 05 Machine torque correction coefficient (constant torque) 100
Par 06 User friction torque 60
Par 07 Maximum coil temperature [°C] 125
Par 08 Minimum revolutions [RPM] 35
Par 09 RPM integration scale 1
Par 10 Filter threshold [RPM] 75
Par 11 Speed ratio (decimal part) 60
Par 12 User friction torque delta 10
Par 13 NOT USED 0