9.5.1.4. Table of configuration parameters
To correctly display the parameter values, you need to load them from the low kit, using the
“Read from low kit” function.
To change the setting, press the CHANGE key and insert the value using the numeric keyboard.
Press ENTER key to confirm or BACK key to back forward.
After any changes to the parameter values, you need to load them in the low kit using the
“Write to low kit” function.
Parameter Description Default values
Par 01 Transmission ratio 141
Par 02 Speed ratio (integer part) 1
Par 03 Minimum braking current (standby pos.) [mA] 0
Par 04 Maximum continuous power [W] 200
Par 05 Machine torque correction coefficient (constant torque) 100
Par 06 User friction torque 60
Par 07 Maximum coil temperature [°C] 125
Par 08 Minimum revolutions [RPM] 35
Par 09 RPM integration scale 1
Par 10 Filter threshold [RPM] 75
Par 11 Speed ratio (decimal part) 60
Par 12 User friction torque delta 10
Par 13 NOT USED 0