EasyManua.ls Logo

TECO F510 series - Group 04 External Analog Input and Output Parameters

TECO F510 series
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-26
Group 04 External Analog Input and Output Parameters
Code Parameter Name Setting Range Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
04-00 AI Input Signal Type
0: AI1: 0~10V
AI2: 0~10V
1 - O O O
1: AI1: 0~10V
AI2: 4~20mA
2: Reserved
3: Reserved
4: AI1: 4~20mA
AI2: 0~10V
*9
5: AI1: 4~20mA
AI2: 4~20mA
*9
04-01
AI1 Signal Scanning and
Filtering Time
0.00~2.00 0.03 s O O O
04-02 AI1 Gain 0.0~1000.0 100.0 % O O O *1
04-03 AI1 Bias -100.0~100.0 0 % O O O *1
04-04 Negative AI
0: Disable
0 - O O O
Note6
1: Enable
04-05 AI2 Function Setting
0: Auxiliary Frequency
0 -
O O O
1: Frequency Reference Gain O O O
2: Frequency Reference Bias O O O
3: Output Voltage Bias O X O
4: Coefficient of Acceleration and
Deceleration Reduction
O
O O
5: DC Braking Current O O X
6: Over-Torque Detection Level O O O
7: Stall Prevention Level During
Running
O
X X
8: Frequency Lower Limit O O O
9: Jump Frequency 4 O O O
10: Added to AI1 O O O
11: Positive Torque Limit X O O
12: Negative Torque Limit X O O
13: Regenerative Torque Limit X O O
14: Positive / Negative Torque
Limit
X O
O
15: Reserved - - -
16: Torque Compensation X O X
17: Reserved - - -
04-06
AI2 Signal Scanning and
Filtering Time
0.00~2.00 0.03 s O O O
04-07 AI2 Gain 0.0~1000.0 100.0 % O O O *1
04-08 AI2 Bias -100.0~100.0 0 % O O O *1
04-09
AI Input Signal Type of I/O
card
0: AI3:0~10V
1: AI3:-10~10V
2: AI3:4~20mA
0 - O O O *10
04-10 AI3 Function Setting
Range and definition are the same
as those of 04-05
10 - O O O *10

Table of Contents