EasyManua.ls Logo

TECO JSDEP Series - Page 34

TECO JSDEP Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-18
(3) CN1 Interface Circuit and Wire Mode:
The diagram below introduces all interface circuit of CN1 and wire-method of host controller.
(a) Digital input interface circuit (IO1):
Digital input interface circuit can be operated by relay or collector transistor circuit. The relay should be the
low electric current, in order to avoid the faulty contacting. External voltage: 24V.
Internal 24V Power External 24V Power
(b) Digital Output Interface Circuit (IO2):
When using external power, please attention to the power polarity. Adverse polarity will case circuit
damage. Digital output is “Open Collector”. The maximum of external voltage is 24V; and the maximum
electric current is 10mA.
Internal 24V Power External 24V Power

Table of Contents

Other manuals for TECO JSDEP Series

Related product manuals