5-44              
5-4-7 Clear the Pulse Offset 
z  In position control mode, parameter Pn315 (Pulse Error clear mode) has three modes 
 can be select. 
z  CLR input contact is used to clear the pulse error as required according to the list below. 
 
Parameter   Name  Setting Description 
Control 
Mode 
0 
When Input CLR contact, clears the pulse error 
value.  
Pe 
1 
When Input CLR contact to cancels the position 
command, Stops the motor rotating, the pulse error 
value is cleared and mechanical Home signal is 
reset. 
Pi 
Pe 
Pn315 
Pulse Error Clear 
Mode 
2 
When Input CLR contact to cancels the position 
command, stops the motor rotating and the pulse 
error value is cleared.  
Pi 
Note: Input contacts status “1”  (ON)  and  “0”  (OFF) 
Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.