5-27              
5-3-12 Other Functions 
When the speed level in CW or CCW directions becomes greater than the value set in  
Cn007 (Speed reached preset), the output contact INS operates.  
 
Speed reached preset 
 
Parameter 
Signal 
Name  Default  Unit  Setting Range  Control Mode
Cn007 
Speed reached 
preset  
Rated rpm 
× 1/3 
rpm 0~4500  S/T 
 
 
Note: Input contacts status “1” (ON) and “0” (OFF). 
Please check section 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection. 
 
Zero Speed preset  
  When the speed is less than the speed set in Sn215 (Value of ZS), the output contact 
ZS operates.  
Parameter 
Signal 
Name  Default  Unit  Setting Range  Control Mode
Sn215  Value of zero speed  50  rpm  0~4500  ALL 
 
 
Note: Input contacts status “1”  (ON)  and  “0”  (OFF) 
Please check section 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.