Field or control Description
Subaddress/Mode Sets the subaddress or mode value for which to search.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Command and Mark When RT Address = Inside Range or
Outside Range
High Address Sets the high address value for which to search.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Command and Mark When RT Address = Inside Range or
Outside Range
Word Count/Mode Count Sets the word count or mode count value for which to search.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Command and Mark When RT Address = Inside Range or
Outside Range
Status Word Bits Sets the status word pattern for which to search.
Tap the field and use the A and B knobs to select and change the values. Selecting a bit shows
a short description of that bit's function.
Only available when Mark On = Status and Mark When RT Address = Inside Range or
Outside Range
Data Sets the data pattern for which to search.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Available when Mark On = Data.
Error Type Sets the error condition for which to search.
Available when Mark On = Error.
Copy Trigger Settings to
Search
Sets the search criteria to match the current oscilloscope trigger settings.
Copy Search Settings to
Trigger
Sets the current oscilloscope trigger settings to match the search criteria.
Menus and dialog boxes
242 MSO54, MSO56, MSO58, MSO58LP, MSO64 Help

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO64 and is the answer not in the manual?

Tektronix MSO64 Specifications

General IconGeneral
BrandTektronix
ModelMSO64
CategoryTest Equipment
LanguageEnglish

Related product manuals