Radiator LED mode Description
Radiator identification
Shows the position of the radiator.
LED 1 shows the port number of the transmitter.
LED 2 and 3 show the position of the radiator on that branch.
LED 2 shows multiples of ten and LED 3 shows the number
zero to nine.
Delay line compensation value
LED 2 and 3 show the delay line compensation value of the radiator.
LED 2 shows multiples of ten and LED 3 shows the number zero to
nine.
Power level
LED 3 shows the power level of the radiator. Zero means power off, one
is reduced power, two is normal power and three is boost power. For
more information on power levels see "Lingua Radiator" on page1.
Current radiator temperature
LED 2 and 3 show the current temperature of the radiator.
LED 2 shows multiples of ten and LED 3 shows the number zero to
nine.
Delay Line Compensation
When two or more radiators have overlapping footprints then the signal of these radiators can cancel each
other out in the overlapping areas. This is the case when the length of the cable differs between the
different radiators, due to the delay of the signal ( ) over the cable. This can lead to black spots, where
you are unable to receive the infrared signal of the radiators using the receivers.
Radiator 2
Radiator 1
No signal
1
2
CONFIG URE RADIATO R SETTING S 76