Page | 10
Some important data
The distance between the central unit CPU5500 and the first
interface unit INT5500 or splitter SPL5525 in the branch,
may maximum be 100 m .
The distance between two splitters SPL5525 may be max.
50m
One branch may maximum consist of 10 interface units or
Splitters (depending of the total length of the system cable).
Longer cable lengths will limit this maximum number (ref:
power calculation)
A mix of INT5500’s and SPL5525’s on the same branch is
allowed
Maximum 10 interpreter units in one branch may be
connected; Longer cable lengths will limit this maximum
number (ref: power calculation)
An interface unit needs 4W, a microphone panel +0.25W
(per panel), a channel selector +1.6W, a loudspeaker +2.4W
an interpreter unit only needs 5W
The voltage of an interface unit may not be lower than 36V