Unit Description
47
Zone 1 Cool, Zone 2 Heat, and Zone
3 Heat
The CIS is closed so high pressure refrigerant
vapor leaves the compressor and flows through
the DPR to the Zone 2 and Zone 3 hot gas lines
and the open HGS2 and HGS3 into the Zone 2
and Zone 3 evaporators. There, the refrigerant
heats the Zone 2 and Zone 3 evaporators and
condenses into high pressure liquid. Because
SLS2 and SLS3 are closed, the liquid refrigerant
flows through LRCV2 and LRCV3, and through
the liquid line to the LLS1.
The LLS1 is open so the refrigerant flows through
the Zone 1 expansion valve into the Zone 1
evaporator. There, the liquid refrigerant cools the
Zone 1 evaporator as it evaporates into low
pressure vapor. The refrigerant returns to the
compressor through the SLS1, Suction Line,
SLCV1 and the accumulator.
In the condensing unit, the CIS valve closes and
opens to regulate head pressure. The purge valve
is opened continuously during heat to drain the
condenser coil.
Zone 1 Evaporator
1F. Zone 1 Liquid Line Solenoid (LLS1)-Open
2F. Zone 1 Liquid Return Check Valve
(LRCV1)-Closed
3F. Zone 1 Suction Line Check Valve
(SLCV1)-Open
4F. Zone 1 Suction Line Solenoid (SLS1)-Open
5F. Zone 1 Hot Gas Solenoid (HGS1)-Closed
Zone 2 Evaporator
1C. Zone 2 Liquid Line Solenoid (LLS2)-Open
2C. Zone 2 Liquid Return Check Valve
(LRCV2)-Open
3C. Zone 2 Suction Line Check Valve
(SLCV2)-Closed
4C. Zone 2 Suction Line Solenoid (SLS2)-Closed
5C. Zone 2 Hot Gas Solenoid (HGS2)-Open
Zone 3 Evaporator
1R. Zone 3 Liquid Line Solenoid (LLS3)-Open
2R. Zone 3 Liquid Return Check Valve
(LRCV3)-Open
3R. Zone 3 Suction Line Check Valve
(SLCV3)-Closed
4R. Zone 3 Suction Line Solenoid (SLS3)-Closed
5R. Zone 3 Hot Gas Solenoid (HGS3)-Open
Condensing Unit
6. Condenser Inlet Solenoid (CIS)-Closed/Open
(Pressure Dependent)
7. Condenser Inlet Check Valve
(CICV)-Closed/Open
8. Condenser Check Valve (CCV)-Closed
9. Purge Valve (PV)-Open
10. Purge Check Valve (PCV)-Open

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King SPECTRUM TS Series and is the answer not in the manual?

Thermo King SPECTRUM TS Series Specifications

General IconGeneral
BrandThermo King
ModelSPECTRUM TS Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals