SPECTRUM™ TS Operation
76
Hourmeter names and definitions are shown below in the order they appear. To return to the Standard Display,
press the EXIT key.
Hourmeter Names And Definitions Hourmeter Name Definition
Total Hours Total number of hours the unit has been turned on (protection hours).
Total Run Hours Total number of hours the unit has run in both diesel and electric mode.
Engine Hours Total number of hours the unit has run in diesel mode.
Electric House Total number of hours the unit has run in electric mode.
Zone 1 Run Hours Total number of hours that Zone 1 has run in both diesel and electric mode.
Includes running null time.
Zone 2 Run Hours Total number of hours that Zone 2 has run in both diesel and electric mode.
Includes running null time.
Zone 3Run Hours Total number of hours that Zone 3 has run in both diesel and electric mode.
Includes running null time.
Total Maintenance Hours 1 User Programmable - The number of hours before a Total Hours
Maintenance Reminder 1 occurs.
Total Maintenance Hours 2 User Programmable - The number of hours before a Total Hours
Maintenance Reminder 2 occurs.
Total Controller Hours Total hours the controller and HMI control panel have been turned on.
Pretrip Reminder Hours User Programmable - number of hours before a Pretrip Reminder occurs.
Engine Maintenance Hours 1 User Programmable - The number of hours before an Engine Hours
Maintenance Reminder 1 occurs.
Engine Maintenance Hours 2 User Programmable - The number of hours before an Engine Hours
Maintenance Reminder 2 occurs.
Electric Maintenance Hours 1 User Programmable - The number of hours before an Electric Hours
Maintenance Reminder 1 occurs.
Electric Maintenance Hours 2 User Programmable - The number of hours before an Electric Hours
Maintenance Reminder 2 occurs.
IMPORTANT: If a programmable hourmeter is not enabled and/or the view for that hourmeter is not turned on, it will not
appear in the display sequence.