Applied Instructions
SET S0
STL S0
SET S1
ST S2
STL S1
STLE
STLE
STL S2
STLE
z STL and STLE should be used in pairs. STL means start of a flow, STLE means end of a
flow.
After executing of SET Sxxx instruction, the flow assigned by these instructions is ON.
After executing RST Sxxx instruction, the assigned flow is OFF.
In flow S0, SET S1 close the current flow S0, open flow S1.
In flow S0, ST S2 open the flow S2, but don’t close flow S0.
When flow turns from ON to be OFF, OFF or reset OUT、PLS、PLF、not accumulate timer
etc. which belongs to the flow.
ST instruction is usually used when a program needs to run more flows at the same time.
In a main program, usually use ST instruction to open a flow.
Flow [SET]、[ST] 、[STL]、 [STLE]
16 bits instruction:SET、ST、STL、STLE 32 bits instruction:-
Suitable Models:
XC1、XC3、XC5
Pointer: S
Soft Unit’s Bound: S0~S