Applied Instructions
209
3, About the high speed counters which don’t support four times frequency in AB phase
high speed counters, please refer to the following table:
z Input Mode of High Speed Counter’s Signal
1,
Input Mode
Increment Mode:
Under increment mode, input pulse signal, the count value increases with each pulse signal.
+1 +1 +1 +1 +1 +1 +1 +1
Pulse Input
ON
OFF
Increment Mode
Pulse+ Direction Input
Mode
AB Phase Mode
C600 C602 C604 C606 C608 C610 C612 C614 C616 C618 C620C622 C624 C626 C628 C630 C632 C634
X000 U U B
X001 Dir A
X002 U
X003 U
X004 U B
X005 U Dir A
XC3-14 PLC MODELS
Increment Mode
Pulse+ Direction Input
Mode
AB Phase Mode
C600 C602 C604 C606 C608 C610 C612 C614 C616 C618 C620C622 C624 C626 C628 C630 C632 C634
X000 U U B
X001 Dir A
X002
XC5-32 PLC MODELS
PLC MODELS High speed counters without four times counter
XC3-14 C630
XC3-24/ XC3-32 C632
XC3 Series
XC3-48/ XC3-60 C630
XC5-32 -
XC5 Series
XC5-48/ XC5-60 C632