Applied Instructions
2, About the definition of high speed counter’s input terminals, please refer to the
following table:
When X input terminals are not used as high speed input port, they could be used as common
input terminals.
[U]---count pulse input [Dir]---count direction judgment (OFF means +, ON means -)
[A]---A phase input [B]---B phase input
Increment Mode
Pulse+ Direction Input
Mode
AB Phase Mode
C600 C602 C604 C606 C608 C610 C612 C614 C616 C618 C620C622 C624 C626 C628 C630 C632 C634
X000 U U B
X001 Dir A
X002
X003 U U B
X004 Dir A
X005
X006 U U B
X007 Dir A
X010
X011 U
X012
U
Increment Mode
Pulse+ Direction Input
Mode
AB Phase Mode
C600 C602 C604 C606 C608 C610 C612 C614 C616 C618 C620C622 C624 C626 C628 C630 C632 C634
X000 U U B
X001 Dir A
X002 U U B
X003 Dir A
X004 U
X005 U
XC3-48、XC3-60 PLC models
XC3-24、XC3-32 AND XC5-48、XC5-60 PLC MODELS