EasyManua.ls Logo

Thinget XC Series - Assign Method of the Set Value; The Time Value; Action

Thinget XC Series
283 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function of each device
T10 K100
X0
MOV K200 D5
T10 D5
X0
X1
Y0
T2
X0
Y0 X0
X0
Y0
T2
K200
T2
T1
T2
Y0
X0
T1
T2
X0
Y0
T1 T2 T1
K10
K20
T10 is a timer with the unit of
100ms. Assign 100 as a constant,
then 0.1s×100=10s timer work.
Write content in indirect data register
to program or input via data switch.
When assigned as power cut retentive
register, please note that voltage low
will cause the set value instable.
Output delay on-off timer
Action
Flicker
Constant assignment (K)
Indirect assignment (D)
Assign
method of
the set value
If X000 activates, Y000 starts flicker output.
T1 controls the OFF time of Y000, T2 controls the ON time of Y000.
When X000 is ON, output Y000
If X000 changes from ON to be OFF, T220 secondswill be delayed, the will
output Y000 cut.
The Time
Value
The count format of Timers T0~T599 is 16 bits linear increment mode
(0~K32 ,767). If the timer’s count value reaches the maximum value K32767,
the timer will stop timing , the timers status will remain the same status.
n
40

Table of Contents

Related product manuals