Sets the paging duration time.
This setting prevents broadcasts from unintentional continuation due to erroneous operation in telephone
paging made using the ZP-001T module.
Set which output channel in what level an audio source at the currently selected input channel should be
output to.
Select the output channel from Channel 1 to 8 (maximum) with the Left or Right shift key, and set the output
level with the Parameter setting knob. By repeating this procedure, output level can be assigned to 2 or more
output channels.
Pressing the output channel ON/OFF key alternately switches the level between "0 dB" and "– ∞."
OUT1 – 2, Max. 8 when T-001Ts are used (default: OUT1)
0 dB (default)
–∞, –70.0 dB to +10.0 dB, 1 dB steps
Setting Range
Output Channel
Assigned Output Level
Set whether or not to sound a one-tone chime before paging.
When set to OFF, the tone does not sound at the paging telephone, either.
ON, OFF (default)
Setting Range
Select the method of activating paging.
• PAGING PORT: Paging is operated if a start signal (no-voltage make signal) is received from the paging
port when the connection between the unit and PABX is established.
• RING SIGNAL: Paging is operated if an IR signal is received when the connection between the unit and
PABX is established. The ZP-001T module functions as a telephone.
PAGING PORT (default), RING SIGNAL
Setting Range
1, 2 (default), 3Setting Range
30 sec, 10 min
Setting Range