GR-5 Configuration
GR-5 Operator’s Manual
3-46
When opening a new log file, the receiver enables the default set of
messages output with the default output period. Both the default set of
messages and the default output period are programmable.
• Period – specifies the time duration of each log file created in
AFRM mode. Values are 60 to 86400 seconds; default value is
3600 seconds.
• Phase – specifies the “phase” (constant time shift) of creating
multiple log files in AFRM mode. Values are 0 to 86400 seconds;
default value is zero seconds.
• Files (total) – a counter that specifies how many multiple log files
must be created in AFRM until this mode automatically turns off.
This counter decrements on every file rotation until it value
becomes zero, then file rotation automatically stops. The counter
initializes with AFRM.
Note that a log file opens immediately after turning AFRM on.
This startup file is not considered a file rotation event; the AFRM
counter will not decrement.
Values are 0 to [2
31
-1]; default value is 0 (zero). Zero means that
an unlimited number of log files are created.
• Files (remain) – specifies the number of files left for the receiver
to create in AFRM. Values are 0 to [2
31
-1]; default value is zero.
• Automatically remove old files – when no free memory is
available to log data, automatically removes the earliest log file.
If this parameter is enabled, then the receiver will erase the file
with the earliest file creation time/date. AFRM must be enabled
to use this FIFO (First-In, First-Out) feature. The default value is
off (disabled).
The receiver’s memory holds up to 3000 files.