MINTER Configuration
P/N 7010-1004
3-47
FN Key Mode parameter Use these two radio buttons to program
how the receiver reacts when pressing the FUNCTION key.
• LED blink mode switch – pressing FUNCTION toggles between
the MINTER’s normal/extended information modes and start/
stop data recording of Static survey.
– FUNCTION pressed for less than 1 second: changes the
information mode (Normal or Extended Information Modes).
– FUNCTION pressed for 1 to 5 seconds: starts or stops data
recording (Static post-processing mode).
• Occupation mode switch – pressing FUNCTION (less than one
second) will insert a message into the corresponding log file,
indicating that the survey type changed from static to kinematic,
or vice versa. If the REC LED blinks green, the current mode is
dynamic, if it blinks orange, the current mode is static. For more
details, see Table 1-2 on page 1-13 and refer to the PC-CDU
Reference Manual.
Initial Data Collection Dynamic Mode parameter These radio
buttons specify the starting occupation type descriptor inserted at the
beginning of receiver files logged. Select Static or Kinematic to
specify that the corresponding log file starts with a static (STOP) or
kinematic (GO, Trajectory) occupation, respectively.
Data Recording Auto-start parameter These radio buttons allow
the user to program the receiver’s behavior in the event of a power
failure.
Table 3-5 on page 3-47 describes the different scenarios available and
the results after power is restored to the receiver. “Specified file”
refers to the file name entered in the Always append to file field.