Configuration
HiPer Pro Operator’s Manual
2-20
Show the power source for the receiver (BATT LED).
Show the status of the modem and if it receives signals (RX
LED).
Use PC-CDU to configure MINTER settings. Refer to the PC-CDU
User’s Manual for other possible MINTER configurations.
1. Connect your receiver and computer. See “Connecting the
Receiver and a Computer” on page 2-10 for this procedure.
2. On the Connection Parameters dialog box, enable RTS/CTS
handshaking (Figure 2-16).
Figure 2-16. Connection Parameters – MINTER Settings
3. Click ConfigurationReceiver then click the MINTER tab, set
the following parameters and click Apply (Figure 2-17 on
page 2-21). See the following pages for descriptions of these
parameters:
Recording interval on page 2-21
Elevation mask for log file on page 2-21
File name prefix on page 2-21
Always append to the file on page 2-22
Files Creation mode on page 2-22
Automatic File Rotation Mode (AFRM) on page 2-22
FN key mode on page 2-23
Initial data collection dynamic mode on page 2-24