MINTER Configuration
P/N 7010-0681
2-23
Files (total) – a counter that specifies how many multiple log files
must be created in AFRM until this mode automatically turns off.
This counter decrements on every file rotation until it value
becomes zero, then file rotation automatically stops. The counter
initializes with AFRM.
Note that a log file opens immediately after turning AFRM on.
This startup file is not considered a file rotation event; the AFRM
counter will not decrement.
Values are 0 to [2
31
-1]; default value is 0 (zero). Zero means that
an unlimited number of log files will be created.
NOTICE
NOTICE
The receiver’s memory holds up to 512 files.
Files (remain) – specifies the number of files left for the receiver
to create in AFRM.
Values are 0 to [2
31
-1]; default value is zero.
Automatically remove old files – when no free memory is
available to log data, automatically removes the earliest log file. If
this parameter is enabled, your receiver will erase the file with the
earliest file creation time/date. AFRM must be enabled to use this
FIFO (First-In, First-Out) feature.
The default value is off (disabled).
FN Key Mode parameter
Use these two radio buttons to program how the receiver will
react when pressing the FN key.
LED blink mode switch – pressing FN will toggle between
the MINTER’s normal/extended information modes and start/
stop data recording of Static survey.
FN pressed for less than 1 second: changes the
information mode (Normal or Extended Information (EI)
Modes).
FN pressed for 1 to 5 seconds: starts or stops data
recording (Static post-processing mode).