INSTRUCTION MANUAL
CV 1DIAL CONTROLLER
KB-50

Other manuals for Topcon KB-50

Questions and Answers

  • J
    Jasmine BradySep 1, 2025
    How to resolve Topcon KB-50 Communication ERROR (Timeout CTS-ON Check: CV THREAD SEND)?
    • Q
      qjenningsSep 1, 2025
      If you are getting a 'Communication ERROR (Timeout CTS-ON Check: CV THREAD SEND). Communication ERROR (Timeout CTS-OFF Check: CV THREAD SEND)' message on your Topcon Controller, it indicates a data transmission error to the visual acuity chart connected through the online system. Check the cable connections between the CV power supply unit and both the KB-50 and the visual acuity chart. Also, verify the serial port settings on the CV power supply unit for the connection to the visual acuity chart. If the issue continues, update the software for the KB-50 and the CV power supply unit to the newest versions.
  • E
    Ethan AndersonSep 1, 2025
    How to troubleshoot Topcon KB-50 Controller Chart/Mask Communication ERROR?
    • T
      Terri AndrewsSep 1, 2025
      If you encounter a 'Chart/Mask : Communication ERROR' on your Topcon Controller, try setting the chart/mask again. Also, verify that the chart connection of KB-50 and the chart connection of the CV power supply unit are set correctly.
  • A
    Alice StoneSep 2, 2025
    What to do if Topcon KB-50 Controller says 'CV is not READY'?
    • M
      Mrs. April Ballard MDSep 2, 2025
      If you see the message 'CV is not READY' on your Topcon Controller, ensure the cable connecting the CV power supply unit to the measuring head, CV-5000, is correctly connected. Also, try turning the switch of KB-50 on again.
  • B
    Brooke BennettSep 3, 2025
    What to do if Topcon Controller says 'Can't reset CV'?
    • L
      Leon KochSep 3, 2025
      If you see the message 'Can't reset CV' on your Topcon Controller, ensure the cable connecting the CV power supply unit to the measuring head, CV-5000, is correctly connected. Then, touch the [Yes] button in the message box to close the setting display.
  • A
    Andrea WatsonSep 3, 2025
    How to fix Topcon KB-50 Controller Initialize ERROR?
    • D
      Diamond TrevinoSep 3, 2025
      If you encounter the message 'Initialize ERROR!!' on your Topcon Controller, and are prompted to change the settings, first, touch the [Yes] button in the message box. Then, check the contents of the setting changed last, or touch the [Default] button on the setting display to return the data to the initial set values, as the contents of setting are not correct.
  • T
    Troy BurkeSep 4, 2025
    What to do if Topcon KB-50 Controller says 'Can't initialize Comm Port for CV'?
    • M
      michael54Sep 4, 2025
      If you encounter the message 'Can't initialize Comm Port for CV' on your Topcon Controller, try turning on the switch of KB-50 again.
  • T
    Timothy KaneSep 4, 2025
    How to fix Topcon KB-50 error 'Language DLL is not correct version'?
    • J
      Jason StevensSep 5, 2025
      If your Topcon Controller displays 'ERROR: Language DLL is not correct version', update the language file to the newest version, as the file, which should display the set language, cannot be used in the KB-50 of the current version.
  • D
    Danielle JonesSep 5, 2025
    How to fix Topcon Controller error 'The font for ××× character is not fount on this system'?
    • B
      browncraigSep 5, 2025
      If your Topcon Controller displays 'The font for ××× character is not fount on this system', it is necessary to update the Operating System of KB-50, as the font, which should display the set language, is not installed in the KB-50 system.
  • W
    William MurraySep 6, 2025
    How to troubleshoot Topcon KB-50 Communication ERROR?
    • J
      johnbowmanSep 6, 2025
      If you see a 'Communication ERROR' on your Topcon Controller, ensure the CV power supply unit is properly connected to the device via cable, as a communication error has occurred against the device connected through the serial method. Also, check the serial port settings on the CV power supply unit for the connection to the device.
  • K
    kburnsSep 6, 2025
    What to do if Topcon KB-50 Controller says 'Initial setting has not been completed yet'?
    • J
      jenniferwrightSep 6, 2025
      If you see the message 'Initial setting has not been completed yet' on your Topcon Controller, touch the [Yes] button and perform setting correctly, as necessary setting is not done correctly.

Summary

Introduction

Precautions

Cautions for Use

Environmental and Storage Conditions

Checkpoints for Maintenance

Display for Safe Use

Safety Cautions

Usage and Maintenance

Usage

Instructions on how to use the instrument correctly.

User Maintenance

Guidelines for maintenance tasks to be performed by the user.

Escape Clause

Disclaimer of responsibility for damages under certain conditions.

Warning Displays and Positions

Trouble Shooting

Trouble Shooting Guide

Checklist for common troubles, conditions, and remedial measures.

Setting and Changing the Software

Data

Settings related to data connection with external devices and initial data.

Chart

Configuration for chart device, chart page registration, and charts used in tests.

Chart Page Registration

Functionality to customize charts displayed on the chart page.

Changing the CC Chart

Procedure to change the chart used for the cross cylinder test.

Mode

Setting the operational mode, display options, and test conditions.

Step

Setting the step quantity for changing refractive power using the controller's dial.

Local & Time

Setting the language, duration time for display, and date/time.

Course Construction

Managing the list of courses and constructing new ones.

Sub View

Setting the display of sub-information like reference data, dial navigation, and help.

Other

Setting other items like lens/occluder, printer, and KB operation.

Specifications & Performance

Specifications

Technical specifications for the KB-50 and CV-5000, including ranges and steps.

Maintenance

Symbol

Explanation of symbols used in the manual and their IEC publication references.

Maintenance and Cleaning

Guidelines for daily checkups and cleaning procedures.

Disposal of Product

Procedure for disposing of the instrument according to local regulations.

Component Names and Functions

Basic Operation Switches

Function Selector Switches

Special Switches

Names on Monitor Screen

Main Data

Data Reference

Mini Help

Dial Information

Auxiliary Lens;PD Display

Touch Panel Unit

Standard Accessories

Preparations

Initial Setting

Procedure for setting the date and time on the instrument.

Preparation Before Measurement

Basic Operation

Flow of Operation

Diagram illustrating the general flow of operations from data input to power off.

Data Input

Detailed steps for inputting data from auto refractometer and lens meter.

Automatic Optometry by Courses

Specify the Test Name and Execute It

Lens Specification and Dial Operation

Specification and Change of Auxiliary Lens

Change of Chart

Specification;Change of Mask and Input of Visual Acuity

Other Functions

Smart CC Function

Explanation of the Smart CC function for automatic astigmatism testing.

Original Courses

Registration of Original Course

Deletion of Chart on the Chart Page

Registration of Program Course

Dimensions and Weight

Purpose of Use, Efficacy or Effect

Electric Rating

System Classification

Reference Material

Symbol

Explanation of symbols used in the manual and their IEC publication references.

End User License Agreement

General Terms

Topcon KB-50 Specifications

General IconGeneral
BrandTopcon
ModelKB-50
CategoryController
LanguageEnglish

Related product manuals