Chapter 7 Register Operations
10
5
Prefix
Register
Description
Data Type
Min Value
Max Value
Default Value
Protection
Modbus
Register
Len=2
R / U
103068pppccc
Unused
General
1936
R / U
103069pppccc
Unused
General
1938
R / U
103070pppccc
Unused
General
1940
R / U
103071pppccc
Output Pulse FCM#
fcm address
Disabled
General
1942
R / U
103072pppccc
Output Pulse Factor
unsigned div 1000
1.000
50.000
10.000
W & M
1944
R / U
103073pppccc
Output Pulse Type
Delivery Type
Gross
W & M
1946
R / U
103074pppccc
Close Blk Val FCM#
fcm address
Disabled
General
1948
R / U
103075pppccc
Blk Val Status FCM
fcm address
Disabled
General
1950
R / U
103076pppccc
Open Blk Val FCM#
fcm address
Disabled
General
1952
R / U
103077pppccc
Unused
General
1954
R / U
103078pppccc
Pump Run FCM#
fcm address
Disabled
General
1956
R / U
103079pppccc
Pump Kill FCM#
fcm address
Disabled
General
1958
R / U
103080pppccc
Pump Status FCM#
fcm address
Disabled
General
1960
R / U
103081pppccc
Alarm Out FCM#
fcm address
Disabled
General
1962
R / U
103082pppccc
Authorized FCM#
fcm address
Disabled
General
1964
R / U
103083pppccc
Permiss FCM#
fcm address
Disabled
General
1966
R / U
103084pppccc
Permiss Out FCM#
fcm address
Disabled
General
1968
R / U
103085pppccc
Meter Factor #1
unsigned div10000
0.8000
1.2000
1.0000
W & M
1970
R / U
103086pppccc
Meter Factor #1 Rate
unsigned int
0
9999
150
W & M
1972
R / U
103087pppccc
Meter Factor #2
unsigned div10000
0.8000
1.2000
1.0000
W & M
1974
R / U
103088pppccc
Meter Factor #2 Rate
unsigned int
0
9999
200
W & M
1976
R / U
103089pppccc
Meter Factor #3
unsigned div10000
0.8000
1.2000
1.0000
W & M
1978
R / U
103090pppccc
Meter Factor #3 Rate
unsigned int
0
9999
400
W & M
1980
R / U
103091pppccc
Meter Factor #4
unsigned div10000
0.8000
1.2000
1.0000
W & M
1982
R / U
103092pppccc
Meter Factor #4 Rate
unsigned int
0
9999
800
W & M
1984
R / U
103093pppccc
# Meter Factors Used
unsigned int
1
4
4
W & M
1986
R / U
103094pppccc
Unused
General
1988