...(some time later)...
Sent:(Q) Received: (041CA18)
Modbus:
Fn=0x03, Read Register 7002 -> (0xC61A)
...(some time later)...
Fn=0x03, Read Register 7002 -> (0xCA1A)
Get driver input and terminating key
Sent:(R960) Received: (0419601111)
Sent:(R961) Received: (041961D)
Modbus:
Fn=0x03, Read Registers 2850 ... 2875
8.2.2 AUTHORIZE A TRANSACTION ON MULTILOAD
Authorize transaction on Multiload
Sent:(T_A) Received: (0T1)
Modbus:
Fn=0x06, Write 0 to Register 7016
Enable available presets
Sent:(MEM0002) Received: (0T1)
Sent:(MEM0012) Received: (0T1)
Sent:(MEM0022) Received: (0T1)
Modbus:
Fn=0x06, Write 2 to Register 7032
Fn=0x06, Write 2 to Register 7033
Fn=0x06, Write 2 to Register 7034
Upload the driver number and any other additional information to be included with stored BOL in Multiload
Sent:(U95000004504) Received: (0T1)
Sent:(U9510001234) Received: (0T1)
Sent:(U952 ) Received: (0T1)
Sent:(U953 ) Received: (0T1)
Sent:(U954 ) Received: (0T1)
Modbus:
Fn=0x16, Write data to Registers 2700 … 2724
Fn=0x16, Write data to Registers 2725 … 2749
Fn=0x16, Write data to Registers 2750 … 2774
Fn=0x16, Write data to Registers 2775 … 2799
Fn=0x16, Write data to Registers 2800 … 2824
8.2.3 READING TOTALIZERS
Sent:(R112000) Received:
(0001120000000010000000010000000000000000000000000000000000010000000000000000000000000000
00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000