Chapter 7 Register Operations
16
1
yymmdd = Year, Month, and Day of log message
hhmmss = Hour, Minute, and Second of log message
…. = Text of log message (max length 80 characters)
Modbus:
Supported through Modbus Extended Services Registers
7.2.44 950 - CURRENT DRIVER CARD NUMBER
In Remote Processing mode, to be populated by host and will be stored with transaction.
In Stand Alone Processing mode, will be populated with user supplied data.
R950 => 0?0950sss…
U950sss… => 0?0
Where:
sss… = Driver card number.
Modbus:
Read/Write Register=2700, Len=25, Characters (sss…)
7.2.45 951..955 - CURRENT DRIVER PROMPT INFORMATION
(Stockholder, Customer, Account, Consignee)
In Remote Processing mode, to be populated by host and will be stored with transaction.
In Stand Alone Processing mode, will be populated with user supplied data.
R951 => 0?0951sss…
U951sss… => 0?0
Where:
sss… = Driver Prompt Data for Stored BOL
Modbus:
Read/Write Register=2725, Len=25, Characters (951-sss…)
Read/Write Register=2750, Len=25, Characters (952-sss…)
Read/Write Register=2775, Len=25, Characters (953-sss…)
Read/Write Register=2800, Len=25, Characters (954-sss…)
Read/Write Register=2815, Len=25, Characters (955-sss…)
7.2.46 960 INPUT DATA
R960 => 0?0960sss…
Where:
sss… = Input data string from the Terminal Escape Code `E.
Modbus:
Read Only Register=2851, Len=25, Characters (sss…)
7.2.47 961 INPUT DATA TERMINATING KEY
R961 => 0?0961c
Where:
C = Terminating Key from the Terminal Escape Code `E
‘A’ = Next
‘B’ = Prev
‘C’ = Abort/Exit