Page #137 background image
Chapter 7 Register Operations
13
7
‘1’ = 8 Data Bits
P = Parity
‘0’ = None
‘1’ = Odd
‘2’ = Even
T = Stop Bits
‘1’ = 1 Stop Bit
‘2’ = 2 Stop Bits
A = Port Assignment
‘0’ = Not in Use
‘1’ = Host
‘2’ = FCMs
‘3’ = Printer
‘4’ = Event Log Printer
‘5’ = Ethernet Pass Thru
‘6’ = Alibi Log
7’ = MASS METER PORT
‘8’ = ALIBI LOG PTB PORT
9’ = GPS (MultiLoad Mobile Only)
C = Connection Type
‘0’ = Single/Master
‘1’ = Multi-dropped Slave
‘2’ = 2-Wire RS485
Modbus:
p=0, Read/Write Register=243, Len=6, Characters (SDPTAC)
p=1, Read/Write Register=249, Len=6, Characters (SDPTAC)
p=2, Read/Write Register=255, Len=6, Characters (SDPTAC)
7.2.14 094 095 NETWORK PRINTER NUMBER OF COPIES
R09p => 0?009p##########
U09p# => 0?0
Where:
p = Printer #1: 4 and Printer #2: 5
# = Number of copies (When reading, the return value is padded to ensure 9 digits are returned)
7.2.15 112 - REAL-TIME PRESET TOTAL GROSS TOTALIZERS
R112ppp => 0?0112pppPPPPPPPPPMMMMMMMMM…CCCCCCCCC…AAAAAAAAA
Where:
ppp = The specified zero-based preset or load arm number (000-011).
PPPPPPPPP = Preset Total Gross Totalizer
MMMMMMMMM… = Meter Total Gross Totalizers (at least 4 meters, 9 digits per totalizer.)
CCCCCCCCC… = Component Total Gross Totalizers (8 components, 9 digits per totalizer.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech MultiLoad II and is the answer not in the manual?

Toptech MultiLoad II Specifications

General IconGeneral
BrandToptech
ModelMultiLoad II
CategoryControl Systems
LanguageEnglish

Related product manuals