U073DDD.DDD.DDD.DDD => 0?0
Where:
DDD.DDD.DDD.DDD = IP Gateway
Modbus: Read/Write Register=054, Len=2, 32-Bit Integer (4 8-bit numbers)
7.2.9 074 – IP HOST
R074 => 0?0074DDD.DDD.DDD.DDD
U074DDD.DDD.DDD.DDD => 0?0
Where:
DDD.DDD.DDD.DDD = IP Host
Modbus: Read/Write Register=056, Len=2, 32-Bit Integer (4 8-bit numbers)
7.2.10 076 – ADMIN PASSWORD
Use the Extended Service Register to change the value
7.2.11 077 – USER PASSWORD
Use the Extended Service Register to change the value
7.2.12 085 – MODEM INITIALIZATION STRING
R085 => 0?0085SSS...
U085SSS… => 0?0
Where:
SSS = ASCII Modem Initialization String (Default "AT&F0&B1&C1&D0S0=1")
Modbus: Read/Write Register=058, Len=40, Characters (SSS…), Null Terminated
7.2.13 091..093 – COMMUNICATION PORT PARAMETERS
R09p => 0?009pSDPTAC
U09pSDPTAC => 0?0
Where:
p = Communication Port (1-3)
S = Communication Speed
‘0’ = 300 BAUD
‘1’ = 1200 BAUD
‘2’ = 2400 BAUD
‘3’ = 4800 BAUD
‘4’ = 9600 BAUD
‘5’ = 19.2K BAUD
‘6’ = 38.4K BAUD
‘7’ = 57.6K BAUD
‘8’ = 115K BAUD
‘9’ = 230K BAUD
D = Data Bits
‘0’ = 7 Data Bits