Chapter 7 Register Operations
14
1
Not Supported
U135rrrs => 0?0135rrr
Where:
rrr = generic register numbered function
s = Set security level (0-9) this can be formatted with up to 8 leading zeroes.
0 Communications
1 Network
2 Alarms
3 Custom Logic
4 Access ID
5 Date Time
6 Trace
7 Alibi Labels
8 Hazard Labels
9 Prompts
10 BOL
11 SD Card
12 Host
13 Factory Defaults
7.2.23 136 ACCESS PARAMETER SECURITY SETTINGS
R136rrr => 0?0136rrrsssssssss
Where:
rrr = generic register numbered function
sssssssss = Security level (zero leading 0-9 relating to 1-10 viewable level)
Modbus:
Not Supported
U136rrrs => 0?0136rrr
Where:
rrr = generic register numbered function
s = Set security level (0-9) this can be formatted with up to 8 leading zeroes.
0 Com0
1 Com1
2 Com2
3 Network
4 Custom Logic
5 Modbus RTU
6 Modbus TCP
Note: these elements can only be set by an ADMIN level. This can be set from the ML front panel by an
admin or by an external access (this list) providing it is set to ADMIN level.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech MultiLoad II and is the answer not in the manual?

Toptech MultiLoad II Specifications

General IconGeneral
BrandToptech
ModelMultiLoad II
CategoryControl Systems
LanguageEnglish

Related product manuals