EasyManua.ls Logo

Toptech MultiLoad II - CONFIGURATION REGISTERS BY LEVEL

Toptech MultiLoad II
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Register Operations
91
SECURITY_COMPLEXITY_TYPE_ALL 7
}
“Display Load Type” Select how the total amount of product being loaded will be displayed on the screen.
Enum{// Enumerated Value Register Value
DISPLAY_LOAD_TYPE_DISABLED 0
DISPLAY_LOAD_TYPE_GROSS 1
DISPLAY_LOAD_TYPE_NET 2
DISPLAY_LOAD_TYPE_MASS 3
}
“SCS Display Type” Select when the SCS Prompts will be displayed, either before or after the load.
Enum{// Enumerated Value Register Value
SCS_PROMPTS_DISPLAY_TYPE_AFTER 0
SCS_PROMPTS_DISPLAY_TYPE_BEFORE 1
}
7.1.2 000 RCU LEVEL CONFIGURATION REGISTERS
Prefix
Register
Description
Data Type
Min
Value
Max
Value
Default
Value
Protection
Modbus
Register
Len=2
R / U
004
Reload ROM Lang File
disable/enable
Enabled
General
1008
R / U
008
Driver Language
language
English
General
1016
R / U
009
Program Mode Language
language
English
General
1018
R / U
010
Card Reader Type
card-reader
1
General
1020
R / U
011
Prox Card Pull Secs
unsigned int
2
30
3
General
1022
R / U
012
Processing Mode
remote processing
Enabled
General
1024
R / U
013
Message Swap Delay
unsigned int
1
60
3
General
1026
R / U
014
Message Hold Delay
unsigned int
1
60
10
General
1028
R / U
015
Max GPS Site Distance
(MultiLoad Mobile Only)
unsigned int
0
10000
200
General
1030
R / U
016
Auto Authorize
disable/enable
Disabled
General
1032
R / U
017
MM/DD/YY Date
disable/enable
Enabled
W & M
1034
R / U
018
Mass Measure Used
mass measure
None
W&M
1036
R / U
019
Load Date From End
disable/enable
Enabled
General
1038
R / U
020
Measure Used
measures
Gallons
W & M
1040
R / U
021
Print Blend Details
unsigned int
0
2
1
General
1042
R / U
022
Compartment Entry
disable/enable
Disabled
General
1044
R / U
023
Config Timeout Mins
unsigned int
0
99
20
General
1046
R / U
024
Print Totalizers
totalizers
None
General
1048
R / U
025
Simulation Mode
disable/enable
Disabled
W & M
1050
R / U
026
Large Prompts
disable/enable
Disabled
General
1052
R / U
027
Confirm Flow Starts
disable/enable
Disabled
General
1054
R / U
028
Display Adtv as CCs
disable/enable
Disabled
General
1056

Table of Contents