Chapter 7 Register Operations
13
8
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset, meter and component gross quantity values will have an implied
two decimal places.
AAAAAAAAA… = Additive Total Gross Totalizers in Thousands, (16 additives, 9 digits per
totalizer.)
Modbus:
Where: p = preset (0-11), m = meter (0-4), c = component (0-7), a=additive (0-15)
Read Only Registers=3000+2*p, Len=2, 32-Bit Integer (PPPPPPPPP)
Read Only Registers=3024+2*(5*p+m), Len=2, 32-Bit Integer (MMMMMMMMM)
Read Only Registers=3144+2*(8*p+c), Len=2, 32-Bit Integer (CCCCCCCCC)
Read Only Registers=3336+2*(16*p+a), Len=2, 32-Bit Integer (AAAAAAAAA)
Note: Last Gross Totalizer register used=3719
7.2.16 113 - REAL-TIME PRESET TOTAL NET TOTALIZERS
R113ppp => 0?0113pppPPPPPPPPPCCCCCCCCC
Where:
ppp = The specified zero-based preset or load arm number (000-011).
PPPPPPPPP = Preset Total Net Totalizer
CCCCCCCCC… = Component Total Net Totalizers (8 components, 9 digits per totalizer.)
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset and component net quantity values will have an implied two
decimal places.
Modbus:
Where: p = preset (0-11), c = component (0-7)
Read Only Registers=3720+2*p, Len=2, 32-Bit Integer (PPPPPPPPP)
Read Only Registers=3744+2*(8*p+c), Len=2, 32-Bit Integer (CCCCCCCCC)
Note: Last Net Totalizer register used=3935
7.2.17 114 - REAL-TIME PRESET TOTAL MASS TOTALIZERS
R114ppp => 0?0114pppPPPPPPPPPCCCCCCCCC
Where:
ppp = The specified zero-based preset or load arm number (000-011).
PPPPPPPPP = Preset Total Mass Totalizer
CCCCCCCCC… = Component Total Mass Totalizers (8 components, 9 digits per totalizer.)
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset and component mass quantity values will have an implied two
decimal places.
Modbus:
Where: p = preset (0-11), c = component (0-7)
Read Only Registers=11720+2*p, Len=2, 32-Bit Integer (PPPPPPPPP)
Read Only Registers=11744+2*(8*p+c), Len=2, 32-Bit Integer (CCCCCCCCC)
Note: Last Mass Totalizer register used=11935
7.2.18 120 - REAL-TIME SAMPLER TOTAL GROSS TOTALIZERS
R120ppp => 0?0112pppSSSSSSSSS
Where:
ppp = The specified zero-based preset or load arm number (000-011).
SSSSSSSSS = Sampler Total Gross Totalizer
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset and component mass quantity values will have an implied two
decimal places.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech MultiLoad II and is the answer not in the manual?

Toptech MultiLoad II Specifications

General IconGeneral
BrandToptech
ModelMultiLoad II
CategoryControl Systems
LanguageEnglish

Related product manuals