EasyManuals Logo

Toptech MultiLoad II User Manual

Toptech MultiLoad II
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Chapter 2 MultiLoad Responses
14
1
st
Register
MSB
1
st
Register
LSB
Next
Register
MSB
Next
Register
MSB
Rx:
MBAP
FN=16
(+128 if
error)
Start
Register
MSB
Start
Register
LSB
Number
Of
Registers
MSB
Number
of
Registers
LSB
1.6.5 ERROR RESPONSES (FN= +128)
Rx:
MBAP
FN+128
Error
Subcode
Error Sub codes are:
1 = Invalid Function Code. Indicates that the use of an invalid or unimplemented function has been
attempted.
2 = Invalid Address Field. Indicates that a read or write was made to an invalid address. Can also
indicate that a read or write to a single register of a 32-bit value has been attempted.
3 = Invalid Data Field. Indicates that an attempt to write an invalid value to a register has occurred.
This error code will also be returned if an attempt is made to change a value under Weights and Measures
control without with W&M switch being in the active state.
4 = Query Processing Failure. This code is not returned.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech MultiLoad II and is the answer not in the manual?

Toptech MultiLoad II Specifications

General IconGeneral
BrandToptech
ModelMultiLoad II
CategoryControl Systems
LanguageEnglish

Related product manuals