REMOTE = 0,
LOCAL =1,
}alarm_to_host_mode_type
Note: only permissive names can be changed, iii=1.
Mmmmmmmmm = Fcm Output Address
Nnnnn = Batch Alarm Mask for Alibilog
Enum{ DISABLED = 0,
ENABLED = 1 }
Modbus:
Not available.
7.2.41 910 – READ EVENT LOG MESSAGE QUEUE
R910 => 0?0910 OR 0?0910ccyymmddhhmmss….
Where: (when a message is pending, see logmsg_queued bit on Q command)
cc = Number of messages remaining in the queue (00-99)
yymmdd = Year, Month, and Day of log message
hhmmss = Hour, Minute, and Second of log message
…. = Text of log message (max length 80 characters)
Modbus:
Read Only Register=2600, Len=2, 32-Bit Integer (cc)
Read Only Register=2602, Len=2, 32-Bit Integer (yymmdd)
Read Only Register=2604, Len=2, 32-Bit Integer (hhmmss)
Read Only Register=2606, Len=80, Characters (ssssssssss)
Note: Last Event Log Message Queue register used=2685
7.2.42 912 – READ W & M CHANGE LOG MESSAGE QUEUE
R912 => 0?0912 OR 0?0912tttccccyymmddhhmm….
Where: (when a message is pending, see wm_logmsg_queued bit on Q command)
ttt = TMS W&M change type (proprietary, do not use)
10 = Temp Offset Change
12 = Transmitter Resolution Change
0 = All Others Changes
cccc = Number of messages remaining in the queue (0000-0999)
yymmdd = Year, Month, and Day of log message
hhmm = Hour and Minute of log message
…. = Text of log message
Modbus:
Supported through Modbus Extended Services Registers.
7.2.43 913 – READ AUDIT LOG MESSAGE QUEUE
R913 => 0?0913 OR 0?0913ccyymmddhhmmss….
Where: (when an audit message is pending, see auditlog_queued bit on Q command)
cc = Number of messages remaining in the queue (00-99)