Chapter 7 Register Operations
15
9
{"*LLEVEL", AUTO_CLEAR}, // 715003
{"*LLLEVEL", AUTO_CLEAR}, // 715004
{"*TK VALVE", AUTO_CLEAR}, // 715005
};
Note: For Modbus, not available.
lll = Alarm Level as:
enum
{
AUTO_CLEAR = 0,
DRIVER_CLEAR = 1,
REMOTE_CLEAR = 2,
PROGRAM_CLEAR = 3,
WM_CLEAR = 4
}alarm_level;
ssssssssssssssssssssssssssssss = Alarm Message (prefix with an *)
Note: Up to 30 UTF-8 bytes to represent a max of 10 characters.
ccccc = Promotion Count (00000=no promotion)
ppppp = Promoted Alarm Level as:
enum
{
AUTO_CLEAR = 0,
DRIVER_CLEAR = 1,
REMOTE_CLEAR = 2,
PROGRAM_CLEAR = 3,
WM_CLEAR = 4
}promoted_alarm_level;
rrrrr = Reset Mode as:
enum
{
AUTH_TRANS = 0,
CLEAR_PROMOTED = 1,
TIME_2_MIN = 2,
TIME_5_MIN = 3,
TIME_15_MIN = 4,
TIME_30_MIN = 5,
TIME_60_MIN = 6,
TIME_3_HOURS = 7,
TIME_6_HOURS = 8,
TIME_12_HOURS = 9,
TIME_24_HOURS = 10,
}alarm_count_reset_mode;
ttttt = Alarm_to_host as