Chapter 8 Communication Trace Example
171
Fn=0x03, Read Registers 4084 … 4091 (Preset Net Volumes)
Etc…
Send end batch command to allow MultiLoad to clear batch totals.
Sent:(MEB000) Received: (0T1)
Modbus:
Fn=0x06, Write Register 7069
When preset state returns to PRESET_IDLE, prompting for next batch can begin again.
8.5 END OF TRANSACTION PROCESSING
8.5.1 ENDING A TRANSACTION ON MULTILOAD
A transaction can be ended by MultiLoad (Driver pulls card) or from the Host with a MET command
End of transaction processing started when RCU state changes to COMPLETING_LOAD.
Sent:(Q) Received: (0C0C23B)
Modbus:
Fn=0x03, Read Register 7000
And uncleared batched will be set to end batch waiting for the host to acknowledge with a MEB command to
clear totals.
When all presets have been cleared, RCU status will go to TRANSACTION_DONE.
Sent:(Q) Received: (0D0C238)
Modbus:
Fn=0x03, Read Register 7000
Reset display to reset RCU status back to idle.
Sent:(T_R) Received: (000)
Modbus:
Fn=0x06, Write 0 to Register 7017
8.6 SHUTDOWN OF HOST SOFTWARE
Sent:(FHOSTDOWN) Received: (000)
Modbus:
Fn=0x03, Write 0 to Register 7014

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech MultiLoad II and is the answer not in the manual?

Toptech MultiLoad II Specifications

General IconGeneral
BrandToptech
ModelMultiLoad II
CategoryControl Systems
LanguageEnglish

Related product manuals