CHAPTER 4 FUNCTION COMMANDS:
FREBOOT = Performs a software reboot of the MultiLoad RCU.
FFACTORY = Restores all MultiLoad registers to factory defaults.
FUPDATEAPPFLASH = Updates the Flash with an uploaded image (req. W&M and a valid image)
Modbus:
Supported through Modbus Extended Services Registers.
FKEYPADON = Enables the keypad on the MultiLoad RCU (default it is active)
FKEYPADOFF = Disables the keypad on the MultiLoad RCU
Write Only Register=7008, Len=1, 16-Bit Integer (any value=FKEYPADON)
Write Only Register=7009, Len=1, 16-Bit Integer (any value=FKEYPADOFF)
FUNCONFIG = Clears the configured RCU status bit.
FRECONFIG = Sets the configured RCU status bit.
Modbus:
Write Only Register=7010, Len=1, 16-Bit Integer (any value=FUNCONFIG)
Write Only Register=7011, Len=1, 16-Bit Integer (any value=FRECONFIG)
FPOWERUP = Resets the power_up RCU status bit. This bit is set on power up.
Modbus:
Write Only Register=7012, Len=1, 16-Bit Integer (any value=FPOWERUP)
FHOSTUP = Sets the host_up RCU status bit. Cleared on power up or when host down
timeout expires between Q commands. Command should be issued when host
system starts communicating with MultiLoad.
Modbus:
Write Only Register=7013, Len=1, 16-Bit Integer (any value=FHOSTUP)
FHOSTDOWN = Clears the host_up RCU status bit. Command should be issued when host
system stops communicating with MultiLoad.
Modbus:
Write Only Register=7014, Len=1, 16-Bit Integer (any value=FHOSTDOWN)
FHOSTWAIT = Bypass host down timer once with alternate timeout.
Modbus:
Write Only Register=7015, Len=1, 16-Bit Integer (any value=FHOSTUP)
FEODLOG = Prints EOD-Report for all totalizers type by arm and also gives the throughput
between the feodlog commands
Modbus:
Write Only Register=7018, Len=1, 16-Bit Integer (any value=FEODLOG)