Chapter 7 Register Operations
95
7.1.4 101 PRESET LEVEL CONFIGURATION REGISTERS
Note: ppp = The specified zero-based preset or load arm number (000-011).
Modbus:
The Modbus Preset Index Register sets the ppp index, Read/Write Register=996, Len=1, 16-Bit Integer
Prefix
Register
Description
Data Type
Min
Value
Max
Value
Default
Value
Protection
Modbus
Register
Len=2
R / U
101000ppp
Number of Meters
unsigned int
1
6
1
General
1400
R / U
101001ppp
Number of Components
unsigned int
1
8
1
General
1402
R / U
101002ppp
Number of Additives
unsigned int
0
16
0
General
1404
R / U
101003ppp
Preset Enabled
disable/enable
Enabled
General
1406
R / U
101004ppp
Blending Type
blend_type
Disabled
General
1408
R / U
101005ppp
W&M Controlled
disable/enable
Disabled
W & M
1410
R / U
101006ppp
Proving Flow Rate
unsigned int
0
9999
600
General
1412
R / U
101007ppp
Excess Flw Alrm Rate
unsigned int
0
9999
1100
General
1414
R / U
101008ppp
Overrun Alarm Vol
unsigned int
0
65535
5
General
1416
R / U
101009ppp
Low Flow Start Vol
unsigned int
0
65535
50
General
1418
R / U
101010ppp
Low Flow Restart Vol
unsigned int
0
65535
15
General
1420
R / U
101011ppp
Low Flow Rate
unsigned int
0
9999
150
General
1422
R / U
101012ppp
High Flow Rate
unsigned int
0
9999
600
General
1424
R / U
101013ppp
Proving Low Flow Vol
unsigned int
0
65535
50
General
1426
R / U
101014ppp
Line Flush Vol
unsigned int
0
65535
0
General
1428
R / U
101015ppp
Line Flush Min Vol
unsigned int
0
65535
0
General
1430
R / U
101016ppp
Line Flush Comp#
unsigned int
0
8
0
General
1432
R / U
101017ppp
Take L.F. from Match
disable/enable
Enabled
General
1434
R / U
101018ppp
Take L.F. from First
disable/enable
Disabled
General
1436
R / U
101019ppp
Take L.F. from Last
disable/enable
Disabled
General
1438
R / U
101020ppp
Compute Blend Density
disable/enable
Disabled
W&M
1440
R / U
101021ppp
Alt. High Flow Rate
unsigned int
0
9999
600
General
1442
R / U
101022ppp
Stop Start Delay
unsigned int
0
65535
0
General
1444
R / U
101023ppp
Blnd Chk Start Vol
unsigned int
0
65535
60
Conditional
1446
R / U
101024ppp
Blnd Chk Restart Vol
unsigned int
0
65535
10
Conditional
1448
R / U
101025ppp
Blnd Chk Alarm %
percent
0.10%
100.00%
5.00%
Conditional
1450
R / U
101026ppp
Blnd Chk Alarm Vol
unsigned int
0
65535
25
Conditional
1452
R / U
101027ppp
Blnd Chk Alarm Time
unsigned int
0
65535
10
Conditional
1454
R / U
101028ppp
Low Flow Start Percentage
percent
0
100
0
General
1456
R / U
101029ppp
Blnd On Lead Comp
Blend_on_lead
0
3
NONE
General
1458
R / U
101030ppp
Blnd Adj Start Vol
unsigned int
0
65535
60
General
1460
R / U
101031ppp
Blnd Adj Restart Vol
unsigned int
0
65535
10
General
1462
R / U
101032ppp
Blnd Adj Dev %
percent
0.00%
100.00%
1.00%
General
1464

Table of Contents