Chapter 7 – Register Operations
96
Prefix
Register
Description
Data Type
Min
Value
Max
Value
Default
Value
Protection
Modbus
Register
Len=2
R / U
101033ppp
Blnd Adj Dev Vol
unsigned int
0
65535
5
General
1466
R / U
101034ppp
Blnd Adj Time
unsigned int
0
65535
5
General
1468
R / U
101035ppp
Proving Low Flow Rate
unsigned int
0
9999
600
General
1470
R / U
101036ppp
Min Preset Value
unsigned long int
0
999999
100
General
1472
R / U
101037ppp
Default Preset Value
unsigned long int
0
999999
0
General
1474
R / U
101038ppp
Max Preset Value
unsigned long int
0
999999
10000
General
1476
R / U
101039ppp
Auto Batch Authorize
disable/enable
Disabled
General
1478
R / U
101040ppp
Deliver Type
Delivery Type
Gross
W & M
1480
R / U
101041ppp
Blk Valve Open Delay
unsigned int
0
65535
0
General
1482
R / U
101042ppp
B.V. Open Alrm Time
unsigned int
2
65535
10
General
1484
R / U
101043ppp
B.V. Close Alrm Time
unsigned int
2
65535
10
General
1486
R / U
101044ppp
Non-Proportional Blending
disable/enable
Disabled
General
1488
R / U
101045ppp
Open Loading
disable/enable
Disabled
General
1490
R / U
101046ppp
Output Pulse FCM#
fcm address
Disabled
General
1492
R / U
101047ppp
Output Pulse Factor
unsigned div 1000
0.001
50.000
10.000
W & M
1494
R / U
101048ppp
Output Pulse Type
Delivery Type
Gross
W & M
1496
R / U
101049ppp
Alt High Flow Start Delay
unsigned int
0
999
0
General
1498
R / U
101050ppp
Alt High Flow Stop Delay
unsigned int
0
999
0
General
1500
R / U
101051ppp
Permissive Alarm Time
unsigned int
0
999
0
General
1502
R / U
101052ppp
Excess Flow Alarm Time
unsigned div 1000
0
65535
0
General
1504
R / U
101053ppp
Unused
General
1506
R / U
101054ppp
BSW 1 Sensor FCM#
fcm address analog input
Disabled
General
1508
R / U
101055ppp
Default BSW
unsigned div 100
0
100.00
0
General
1510
R / U
101056ppp
Alarm Low BSW 1
signed div 100
-10.00
110.00
-10.00
General
1512
R / U
101057ppp
Alarm High BSW 1
signed div 100
-10.00
110.00
110.00
General
1514
R / U
101058ppp
BSW Alarm Time
unsigned int
0
60
0
General
1516
R / U
101059ppp
BSW 1 @ Low Value
unsigned div 100
0
100.00
0
General
1518
R / U
101060ppp
BSW 1 @ High Value
unsigned div 100
0
100.00
100.00
General
1520
R / U
101061ppp
BSW 1 Offset
signed div 100
-3.00
3.00
0
General
1522
R / U
101062ppp
Unused
General
1524
R / U
101063ppp
BSW 2 Sensor FCM#
fcm address analog input
Disabled
General
1526
R / U
101064ppp
BSW Alarm Volume
unsigned int
0
9999999
0
General
1528
R / U
101065ppp
Alarm Low BSW 2
unsigned div 100
-10.00
110.00
-10.00
General
1530
R / U
101066ppp
Alarm High BSW 2
unsigned div 100
-10.00
110.00
110.00
General
1532
R / U
101067ppp
Unused
General
1534
R / U
101068ppp
BSW 2 @ Low Value
unsigned div 100
0
100.00
0
General
1536
R / U
101069ppp
BSW 2 @ High Value
unsigned div 100
0
100.00
100.00
General
1538